
Add to Cart
PTFE Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
1. What are Electromagnetic Flow Meters?
Electromagnetic flow meters, also called mag meters or magnetic meters, are volumetric flow meters which do not have any moving parts to wear, reducing the need for maintenance or replacement. Accuracy over a wide flow range can be as good as ± 0.5% of flow rate or better.
They feature an obstruction-free design which eliminates flow impediment, and operate with electrodes embedded on opposite sides of the flow tube or sensor to pick up the signal. Mag meters perform extremely well in many municipal and processing applications, and have become the meter of choice for measuring conductive liquids such as water or slurry.
2. Advantages & Disadvantages Electromagnetic Flow Meters
There are numerous benefits to using electromagnetic flowmeters to perform fluid flow measurements. They are generally non-invasive and have no moving parts, reducing the risk of breakdowns and the frequency of repairs. A decrease in flowmeter pressure is also usually no greater than that of an equivalent pipe length, reducing the piping costs. Some of the other major advantages provided by magnetic flowmeters include:
Despite these advantages, magnetic flowmeters also present certain difficulties for flow rate measurement. These flowmeters are only effective on conductive fluids, and materials such as unmixed hydrocarbons and gases cannot be measured. However, magnetic materials themselves may also present problems, as hydrodynamic effects can alter the normal flow pattern and disturb the velocity rate enough to interfere with operations. Depending on their size and capacity, magnetic flowmeters can be relatively heavy, and those with higher corrosion and abrasion resistance can be expensive.
3.What is the operating principle of a magnetic flow meter?
The operation of a magnetic flow meter or mag meter is based upon Faraday's Law, which states that the voltage induced across any conductor as it moves at right angles through a magnetic field is proportional to the velocity of that conductor.
As applied to the design of magnetic flow meters, Faraday’s Law indicates that signal voltage (E) is dependent on the average liquid velocity (V) the magnetic field strength (B) and the length of the conductor (D) (which in this instance is the distance between the electrodes).
Faraday's Formula
E is proportional to V x B x D where:
E = The voltage generated in a conductor
V = The velocity of the conductor
B = The magnetic field strength
D = The length of the conductor
To apply this principle to flow measurement with a magnetic flow meter, it is necessary first to state that the fluid being measured must be electrically conductive for the Faraday principle to apply.
As applied to the design of magnetic flow meters, Faraday's Law indicates that signal voltage (E) is dependent on the average liquid velocity (V) the magnetic field strength (B) and the length of the conductor (D) (which in this instance is the distance between the electrodes).
In the case of wafer-style magnetic flow meters, a magnetic field is established throughout the entire cross-section of the flow tube. If this magnetic field is considered as the measuring element of the magnetic flow meter, it can be seen that the measuring element is exposed to the hydraulic conditions throughout the entire cross-section of the flow meter.
With insertion-style flow meters, the magnetic field radiates outward from the inserted probe.
4. Specification
MLF Type | Divided Type | Integrated Type | Explosive Proof Integrated Type | Battery Powered Type | Heat Energy Type |
Accuracy | ±0.2% or ±0.5% | ||||
Pipeline Diameter | DN10-DN2000 | DN10-DN600 | DN25-DN2000 | ||
Flange | GB, ANSI, JIS, BS, Others | ||||
Pressure | DN10-DN600 1.0 1.6 2.5 4.0MPa | ||||
DN700-DN2000 0.6 1.0 1.6MPa | |||||
Liner Material | CR, PTFE, PU, Hard Rubber, PFA, FEP(F46) | ||||
Conductivity | ≥5µs/cm(Please contact us if it is less than 5µs/cm) | ||||
Electrode | 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others | ||||
Protection Class | IP65, IP66, IP67, IP68 | ||||
Medium Temperature | -25~180℃ (Please refer to liner material) | -25~80℃(Please refer to liner material) | -25~180℃ (Please refer to liner material) | ||
Ambient Temperature for Accuracy Influence | <±0.1%/10℃ or <±0.25%/10℃ at the ambient temperature of -25~60℃ | ||||
Repetability | ≤±0.1% or ±0.25% | ||||
Analog Output Error | ≤±0.02mA | ||||
Velocity | 0.3~10m/s | ||||
Electrical connection | M20x1.5 Seal Cartridge, GB1/2, NPT1/2 | ||||
Output | 4-20mA, Pulse, RS485, Hart, Profibus |
5. How to select and install a magnetic flow meter?
The key questions which need to be answered before selecting a magnetic flow meter are:
6. In-Line Magnetic Flow Meters installation Considerations
In-line flow meters do not require as much straight pipe as the insertion styles. A minimum of 5 to 10 pipe diameters of straight run upstream and 1 to 2 diameters downstream is recommended. In vertical pipe runs, flow should always run up and not down. These flow meters are very sensitive to air bubbles. The magnetic flow meter cannot distinguish entrained air from the process fluid; therefore, air bubbles will cause the mag flow meter to read high.
7.Company Profile
Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.
Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.
We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.
We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.
Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.
8. FAQ
Q: How long will you give me the reply?
A: We will contact you in 5 hours as soon as we can.
Q: What is the warranty of your prducts?
A: Our warranty is 12 months after the shipping date.
Q: What is the lead time of your products?
A: Normally our factory lead time is 10-12 working days.
Q: Can I OEM your products?
A: OEM and ODM customization are welcomed.
Q: What is your MOQ?
A: We have no MOQ limit, small quantity order is acceptable.
Q:What is the transport?
A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.