Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.

Manufacturer from China
Site Member
6 Years
Home / Products / Electromagnetic Flow Meter /

DN100mm 4'' Mag Flow Meter Principle Of Operation 4-20mA Flange Type

Contact Now
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MsNancy Zhao
Contact Now

DN100mm 4'' Mag Flow Meter Principle Of Operation 4-20mA Flange Type

Ask Latest Price
Video Channel
Model Number :MLF
Place of Origin :China
MOQ :1pc
Price :Negotiation
Payment Terms :T/T
Supply Ability :500pcs per month
Delivery Time :7-10 working days
Packaging Details :In Carton or Wooden Box
Product Name :Water Electromagnetic Flowmeter
Pipeline Diameter :150
Accuracy :0.5%
Output :4-20mA / Pulse / RS485
Electrode :316SS, Hc, Ta, Ti, Others
IP Class :IP65/IP68
Power supply :220VAC/110VAC, Battery
Connection :Flange, Clamp, Thread, Clamping
Type :Electromagnetic Flow Meter
Medium :Sea water, Conductive Fluid, Liquid, Milk Beer Drink Water, Conductivity>0.5us/㎡
Pressure :0.6MPa,1.0MPa,1.6MPa,2.5MPa,4.0MPa
Working pressure :1.6MPa, DIN, JIS
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

DN100mm 4'' Mag Flow Meter Principle Of Operation 4-20mA Flange Type

1. Introduction

MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.

DN100mm 4'' Mag Flow Meter  Principle Of Operation 4-20mA Flange Type

2.Working Principle

The principle of the sensor is based on Faraday’s law of electromagnetic induction.It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)E=KBDV

E——Induced electromotive force,V;

K——meter constant;

B——Magnetic flux density,T;

D——Internal diameter of measuring pipe,m;

V——Average velocity of pipe section,m/s.

MLF Series Electromagnetic Flow Meter

Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,K is meter constant,K=4kB/πD.

Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current.E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

4. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

5.Company Profile

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.


Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.

We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.

We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.

Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.

DN100mm 4'' Mag Flow Meter  Principle Of Operation 4-20mA Flange Type

DN100mm 4'' Mag Flow Meter  Principle Of Operation 4-20mA Flange Type

DN100mm 4'' Mag Flow Meter  Principle Of Operation 4-20mA Flange Type

6.FAQ

Q: How long will you give me the reply?
A: We will contact you in 5 hours as soon as we can.

Q: What is the warranty of your prducts?
A: Our warranty is 12 months after the shipping date.

Q: What is the lead time of your products?
A: Normally our factory lead time is 10-12 working days.

Q: Can I OEM your products?
A: OEM and ODM customization are welcomed.

Q: What is your MOQ?
A: We have no MOQ limit, small quantity order is acceptable.

Q:What is the transport?
A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.

DN100mm 4'' Mag Flow Meter  Principle Of Operation 4-20mA Flange Type

Inquiry Cart 0