Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.

Manufacturer from China
Site Member
6 Years
Home / Products / Electromagnetic Flow Meter /

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

Contact Now
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MsNancy Zhao
Contact Now

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

Ask Latest Price
Video Channel
Model Number :MLF
Place of Origin :China
MOQ :1pc
Price :Negotiation
Payment Terms :T/T
Supply Ability :500pcs per month
Delivery Time :7-10 working days
Packaging Details :In Carton or Wooden Box
Product Name :Water Electromagnetic Flowmeter
Pipeline Diameter :150
Accuracy :0.5%
Output :4-20mA / Pulse / RS485
Electrode :316SS, Hc, Ta, Ti, Others
IP Class :IP65/IP68
Power supply :220VAC/110VAC, Battery
Connection :Flange, Clamp, Thread, Clamping
Type :Electromagnetic Flow Meter
Medium :Sea water, Conductive Fluid, Liquid, Milk Beer Drink Water, Conductivity>0.5us/㎡
Pressure :0.6MPa,1.0MPa,1.6MPa,2.5MPa,4.0MPa
Working pressure :1.6MPa, DIN, JIS
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

1. Introduction

MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

2. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

3. Selection of Liner Material

Liner Material Main Performance Application
PTFE

1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

2. Low abrasion resistance.

3. Low negative pressure resistance

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CR Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

2 Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

4. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

5. Maintance

The electromagnetic flowmeter has a self-diagnostic function. In addition to power supply and hardware circuit failures, the system also alarms other failures in general use. These messages will give corresponding prompts in the lower right corner of the screen.


1 Maintenance and repair
a) The sensor installation site should meet the requirements of Section 4, please keep the housing tidy;
b) The transmitter should be placed in a clean, ventilated and dry place;
c) It needs to be inspected every two years. For high-precision users, the instrument needs to be submitted for review.

2 Transportation and storage
a) The instrument must be packaged before transportation, and be handled with care when loading and unloading.
b) The storage place must be dry and ventilated to avoid corrosive gases, and the ambient temperature should not be too low or too high;
c) The storage time should not exceed three years.

3. Unpacking inspection
a) The package cannot be opened with a heavy hammer, be careful not to damage the instrument
b) Check the contents carefully according to the packing list.

6.Company Profile

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.


Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.

We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.

We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.

Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

7.FAQ

Q: How long will you give me the reply?
A: We will contact you in 5 hours as soon as we can.

Q: What is the warranty of your prducts?
A: Our warranty is 12 months after the shipping date.

Q: What is the lead time of your products?
A: Normally our factory lead time is 10-12 working days.

Q: Can I OEM your products?
A: OEM and ODM customization are welcomed.

Q: What is your MOQ?
A: We have no MOQ limit, small quantity order is acceptable.

Q:What is the transport?
A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.

DN200 Flange Type Magnetic Type Flow Meter With Carbon Steel Material

Inquiry Cart 0