Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.

Manufacturer from China
Site Member
6 Years
Home / Products / Electromagnetic Flow Meter /

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Contact Now
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MsNancy Zhao
Contact Now

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Ask Latest Price
Video Channel
Model Number :MLF
Place of Origin :China
MOQ :1pc
Price :Negotiation
Payment Terms :T/T
Supply Ability :500pcs per month
Delivery Time :7-10 working days
Packaging Details :In Carton or Wooden Box
Product Name :Water Electromagnetic Flowmeter
Pipeline Diameter :50
Accuracy :0.5%
Output :4-20mA / Pulse / RS485
Electrode :316SS, Hc, Ta, Ti, Others
IP Class :IP65/IP68
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

1.Working Principle

The principle of the sensor is based on Faraday’s law of electromagnetic induction.It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)E=KBDV

E——Induced electromotive force,V;

K——meter constant;

B——Magnetic flux density,T;

D——Internal diameter of measuring pipe,m;

V——Average velocity of pipe section,m/s.

MLF Series Electromagnetic Flow Meter

Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,K is meter constant,K=4kB/πD.

Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current.E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.

2. Quick Details

MLF electromagnetic flowmeter is explosion-proof design.

Function of low conductivity measurement.

There are nine languages options to meet the needs of different customers.

It has the function of self-regulation and self-examination.

Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

4. Selection of Liner Material

Liner Material Main Performance Application
PTFE

1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

2. Low abrasion resistance.

3. Low negative pressure resistance

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CR Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

2 Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

5. Dimensional Sketches

a. Dimension of Converter

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Divided Type

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Integrated Type

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Battery Powered Type

b. Dimension of Sensor

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

6.Company Profile

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.


Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.

We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.

We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.

Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

7.FAQ

Q: How long will you give me the reply?
A: We will contact you in 5 hours as soon as we can.

Q: What is the warranty of your prducts?
A: Our warranty is 12 months after the shipping date.

Q: What is the lead time of your products?
A: Normally our factory lead time is 10-12 working days.

Q: Can I OEM your products?
A: OEM and ODM customization are welcomed.

Q: What is your MOQ?
A: We have no MOQ limit, small quantity order is acceptable.

Q:What is the transport?
A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.

TriCover And ANSI Flanges Magnetic Water Flow Meter With DN200mm

Inquiry Cart 0