Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.

Manufacturer from China
Site Member
6 Years
Home / Products / Capacitance Level Transmitter /

Professional Capacitance Type Level Transmitter Wide Measuring Range Pressure Level Transmitter

Contact Now
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MsNancy Zhao
Contact Now

Professional Capacitance Type Level Transmitter Wide Measuring Range Pressure Level Transmitter

Ask Latest Price
Video Channel
Model Number :ML3000S
Place of Origin :China
MOQ :1pc
Price :Negotiation
Payment Terms :T/T
Supply Ability :10000pcs per month
Delivery Time :7-10 working days
Packaging Details :In Carton Packing
Product Name :Capacitance Level Transmitter
Application :Liquid, gas, steam
Accuracy :0.5% or 0.075%
Static Pressure :4, 10, 25, 32MPa
Process Connection :Flange type
Sensor :Capacitive sensor
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Flange Mounting Intelligent Capacitance Level Transmitter with Wide Measuring Range

1. Introduction

The mounting of ML3000S flanged liquid level transmitter executes ANSI standard. It has 3” and 4” flanged specifications and has 150LB(2.5MPa) flange class. Regarding to specific installation dimension, please see the bellowed drawing. If users apply GB9116-88 standard, please note: DN=80, PN=2MPa. Material of the contacting liquid diaphragm: 316L, Hastelloy C-276, Monel, Tantalum and so on.

If customer don’t have clear indication, we will supply mounting flange of 3” specification, 150LB and 316L contacting liquid diaphragm.

2. Configuration

Type Specification Code Illustration
ML3¨¨¨S --------------------------------- Flange Mounting Intelligent Liquid Level & Pressure Transmitter
Accuracy 3-------------------------------- ±0.5%
0-------------------------------- ±0.075%
Output 5-------------------------------- 4-20mA, HART
Sensor 1-------------------------------- Capacitive Sensor
S--------------------------------
Connection Medium Mode L-------------------------------- Mounting Flange Type
Measuring Range 4-------------------------------- 0-6.2~37.4KPa(0-635~3810mmH2O)
5-------------------------------- 0-31.1~186.8KPa(0-3175~19050mmH2O)
6-------------------------------- 0-117~690KPa(0-1.2~7Kgf/cm2)
Flange Dimension & Isolation Diaphragm Nominal Diameter Insertion Depth Isolation Diaphragm
A0-------------------------------- 80mm Flat 316 SS
A2-------------------------------- 80mm 50 316 SS
A4-------------------------------- 80mm 100 316 SS
A6-------------------------------- 80mm 150 316 SS
B0-------------------------------- 100mm Flat 316 SS
B2-------------------------------- 100mm 50 316 SS
B4-------------------------------- 100mm 100 316 SS
B6-------------------------------- 100mm 150 316 SS
C0-------------------------------- 80mm Flat Hastalloy C
C2-------------------------------- 80mm 50 Hastalloy C
C4-------------------------------- 80mm 100 Hastalloy C
C6-------------------------------- 80mm 150 Hastalloy C
D0-------------------------------- 100mm Flat Hastalloy C
D2-------------------------------- 100mm 50 Hastalloy C
D4-------------------------------- 100mm 100 Hastalloy C
D6-------------------------------- 100mm 150 Hastalloy C
E0-------------------------------- 80mm Flat Tantalum
F0-------------------------------- 100mm Flat Tantalum
Flange Dimension A-------------------------------- 3" 150lB
B-------------------------------- 4" 150lB
C-------------------------------- 3" 300lB
D-------------------------------- 4" 300lB
Q-------------------------------- Other requirements
Display Header D-------------------------------- Multiple Parameters and Methods Digital LED Display Header
N-------------------------------- No Display Header
Electrical Interface 5-------------------------------- M20*1.5 Waterproof Concentrator
Additional Type -NF1---------------------------- Ex-proof Security Certification: Exd II CT6
-NS1---------------------------- Intrinsic Safety Certification: Exi II CT4
-M------------------------------- Other requirements are available
Remarks:
e.g.:ML3051SL-5A0AD5-NF1

3. Dimension

Professional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level TransmitterProfessional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level Transmitter Professional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level Transmitter

Professional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level Transmitter Professional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level Transmitter

Professional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level Transmitter Professional Capacitance Type Level Transmitter  Wide Measuring Range Pressure Level Transmitter

The flange gasket is chosen by customers according to connecting liquid medium features. Our company recommends Asbestos Rubber,Nitrile Rubber, Fluorine Rubber, Nylon, Teflon and so on.

Inquiry Cart 0