Add to Cart
DN80 Integrated EMF Electromagnetic Flow Meter with Cheap Price China
1. Introduction
1. The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a transducer. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μS/cm (tap water, raw water conductivity of about 100 ~ 500μS/cm), can also be used to measure acid, alkali, salt water, pulp or pulp and other media. However, these media should not contain large amounts of magnetic material and air bubbles.
MLF electromagnetic flowmeter is a kind of instrument to measure liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries flow measurement.
2. Quick Details
1). It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.
2). It has the function of low conductivity measurement.
3). It has the consistency of converter’s interchange, which can avoid input parameters repeatedly.
4). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).
5). It is the first domestic company that adopts the function of saving settings before delivery,which can avoid the loss of the parameters.
6). It adopts the international leading excitation technology, which circuit is simple, stable,and reliable.
7). It has the function of infrared remote control and button operation so as to make the operation more convenient.
8). It provides the function of zero correction of sensor and automatic zero adjustment.
9). It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages for option to satisfy different customers’ requirements.
3. Specification
MLF Type | Divided Type | Integrated Type | Explosive Proof Integrated Type | Battery Powered Type | Heat Energy Type |
Accuracy | ±0.2% or ±0.5% | ||||
Pipeline Diameter | DN10-DN2000 | DN10-DN600 | DN25-DN2000 | ||
Flange | GB, ANSI, JIS, BS, Others | ||||
Pressure | DN10-DN600 1.0 1.6 2.5 4.0MPa | ||||
DN700-DN2000 0.6 1.0 1.6MPa | |||||
Liner Material | CR, PTFE, PU, Hard Rubber, PFA, FEP(F46) | ||||
Conductivity | ≥5µs/cm(Please contact us if it is less than 5µs/cm) | ||||
Electrode | 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others | ||||
Protection Class | IP65, IP66, IP67, IP68 | ||||
Medium Temperature | -25~180℃ (Please refer to liner material) | -25~80℃(Please refer to liner material) | -25~180℃ (Please refer to liner material) | ||
Ambient Temperature for Accuracy Influence | <±0.1%/10℃ or <±0.25%/10℃ at the ambient temperature of -25~60℃ | ||||
Repetability | ≤±0.1% or ±0.25% | ||||
Analog Output Error | ≤±0.02mA | ||||
Velocity | 0.3~10m/s | ||||
Electrical connection | M20x1.5 Seal Cartridge, GB1/2, NPT1/2 | ||||
Output | 4-20mA, Pulse, RS485, Hart, Profibus |
4. Selection of Electrode Materials
Electrode Material | Main Performance |
316L | Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on. |
Hb | Good resistance to all concentrations of hydrochloric acid below boiling point, as well as non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid. |
Hc | Corrosion resistance of oxidizing acids, such as nitric acid and mixed acid. A mixture of chromic acid and sulfuric acid, oxides, such as Fe3+,Q3+, and other oxidants, such as a mixture of hypochlorite solution above normal temperature and seawater. |
Ti | Resistant to corrosion of seawater, various chlorides, hypochlorite, oxidizing acids (including fuming nitric acid), organic acids or bases, but not pure reductive acids (e.g., sulfuric acid, hydrochloric acid) etc. but if the acid contains oxidants (such as nitric acid, Fe3,Q3), the corrosion resistance will decrease. |
Ta | Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid. |
Pt-Ir | Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium |
Tungsten Carbide | For pulp and sewage, good resistance to solid particle interference. |
5. Dimensional Sketches
a. Dimension of Converter
Divided Type
Integrated Type
Battery Powered Type
b. Dimension of Sensor
Pipeline Diameter | Dimension | ||
L | W | H | |
15 | 160 | 95 | 130 |
20 | 160 | 105 | 137 |
25 | 160 | 115 | 150 |
32 | 160 | 135 | 160 |
40 | 200 | 145 | 175 |
50 | 200 | 160 | 185 |
65 | 200 | 180 | 205 |
80 | 200 | 195 | 215 |
100 | 250 | 215 | 235 |
125 | 250 | 245 | 275 |
150 | 300 | 280 | 300 |
200 | 350 | 335 | 355 |
250 | 400 | 400 | 405 |
300 | 500 | 455 | 460 |
350 | 500 | 515 | 520 |
400 | 600 | 575 | 580 |
450 | 600 | 635 | 630 |
500 | 600 | 710 | 685 |
600 | 600 | 835 | 795 |
700 | 700 | 905 | 910 |
800 | 800 | 1020 | 1030 |
900 | 900 | 1120 | 1120 |
1000 | 1000 | 1245 | 1250 |
1200 | 1200 | 1465 | 1470 |
6. Configuration
MLF Series Electromagnetic Flow Meter Configuration | |||||||||||||||||||||||
Model | MLF | ||||||||||||||||||||||
Sensor Installation | S | Flange Type Sensor | |||||||||||||||||||||
C | Insertion Type Sensor | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipeline Diameter | 10 | 10mm | |||||||||||||||||||||
15 | 15mm | ||||||||||||||||||||||
20 | 20mm | ||||||||||||||||||||||
...... | |||||||||||||||||||||||
2000 | 2000mm | ||||||||||||||||||||||
Electrode Installation | F | Standard Fixed Type | |||||||||||||||||||||
Electrode Material | A | 316L SS | |||||||||||||||||||||
B | Hb | ||||||||||||||||||||||
C | Ta | ||||||||||||||||||||||
D | Ti | ||||||||||||||||||||||
E | Hc | ||||||||||||||||||||||
F | Tungsten Carbide | ||||||||||||||||||||||
G | Others | ||||||||||||||||||||||
Liner Material | R | Rubber | |||||||||||||||||||||
P | PTFE | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipe Material | B | 304 SS (Standard) | |||||||||||||||||||||
C | 316 SS | ||||||||||||||||||||||
Flange Type | G | GB (Standard) | |||||||||||||||||||||
A | ANSI | ||||||||||||||||||||||
J | JIS | ||||||||||||||||||||||
B | BS | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Flange Material | A | 304 SS | |||||||||||||||||||||
B | 316 SS | ||||||||||||||||||||||
C | #20 Carbon Steel (Standard) | ||||||||||||||||||||||
Cover Material | D | 304 SS | |||||||||||||||||||||
E | 316 SS | ||||||||||||||||||||||
F | Carbon Steel+ Epoxy Metallic Paint (Standard) | ||||||||||||||||||||||
Matching Flange | 0 | Without Matching Flange (Standard) | |||||||||||||||||||||
1 | With Matching Flange | ||||||||||||||||||||||
Ground Ring | 0 | Without Ground Ring (Standard) | |||||||||||||||||||||
1 | With Ground Ring | ||||||||||||||||||||||
Rated Pressure | 10 | 1.0MPa | |||||||||||||||||||||
16 | 1.6MPa | ||||||||||||||||||||||
25 | 2.5MPa | ||||||||||||||||||||||
40 | 4.0MPa | ||||||||||||||||||||||
Working Temperature | E | ≤60℃ | |||||||||||||||||||||
H | ≤180℃(Divided Type) | ||||||||||||||||||||||
Type | I | Integrated Type | |||||||||||||||||||||
D | Divided Type | ||||||||||||||||||||||
Output | P | Pulse | |||||||||||||||||||||
A | 4-20mA | ||||||||||||||||||||||
G | RS485 | ||||||||||||||||||||||
H | Hart | ||||||||||||||||||||||
Q | Others | ||||||||||||||||||||||
Power Supply | 0 | 220VAC | |||||||||||||||||||||
1 | 24VDC | ||||||||||||||||||||||
2 | Battery-powered | ||||||||||||||||||||||
Protection Class | 0 | IP65 (Integrated/Divided Type) | |||||||||||||||||||||
1 | IP67 (Divided Type) | ||||||||||||||||||||||
2 | IP68 (Divided Type) | ||||||||||||||||||||||
Other Features | R | Heat Energy Function | |||||||||||||||||||||
P | With PT1000 | ||||||||||||||||||||||
B | Without PT1000 | ||||||||||||||||||||||
Explosion Proof | 0 | None | |||||||||||||||||||||
EX | Explosive Proof |